C-LINE MARINE BATTERY CHARGERS MENU:


System LM/HE Charging principle WU
C-Line Battery Charger for marine and stationary purposes

System HE Charging principle IU
C-Line Battery Charger for marine and stationary purposes

   





























C-Line Battery Charger for marine and stationary purposes
SYSTEM LM/HE
Charging principle WU
Back to menu:

FULLAUTOMATIC * * * * * * * * * * * SOFT START

GENERAL
The latest development in the electronic area have been used for these battery chargers. The demand of the battery manufactures has been fulfilled, so the battery obtains highest possible capacity.
N.B. The battery charger may only be connected to the DC voltage for which it is designed. (Look up the rating plate).

RANGE OF APPLICATION
Charging of:
Lead/acid batteries
Sealed maintenancefree batteries
Ni-Cd batteries and so on

CHARGING PRINCIPLE, WU
Charges in accordance to DIN 41774/ 41773,
decreasing current/constant voltage.


CONNECTION
1. Connect the charging cable to the battery by a firm connection.
2. Connect the mains.
The charging soft start (red and yellow LED 1 flashes) and after 5 seconds the charging is in function. (Red LED is illuminated).

N.B. The battery charger may only be connected to the DC voltage for which it is designed. (Look up the rating plate).

THE CHARGING EVENT
When the charging has started, the fullautomatic battery charger runs and controls the whole charging event. At consumption the battery charger charges automatically again. The event can be followed by the coloured LED's.



Red LED:
- illuminates by main charging
- flashes by error

Yellow LED 1:
- illuminates when the given voltage has been reached

Yellow LED 2:
- illuminates by I < 30%

Green LED:
- illuminates when the battery is fully charged
- flashes if low battery voltage
- flashes for missing battery

Red and yellow LED 1:
- flashing while soft start (about 5 seconds)

DISCONNECTION OF BATTERY
Turn off the mains to the battery
charger if you disconnect the battery.
LED INDICATION: Back to menu:
Red LED:
- illuminates by main charging
- flashes by error
- flashes by to high battery voltage

Mains and battery connected correct

Battery voltage is higher than the
adjusted value
Yellow LED 1:
- lilluminates when the given voltage has been
reached


The gassingpoint of the battery has
been reached

Yellow LED 2:
- illuminates by I < 30%

Main current is less than 30% of
nominal current
Green LED:
- illuminates when the battery is fully charged

- flashes if low battery voltage
- flashes for missing battery

The battery is ready for use
The connected battery voltage < 0,5 V/C

Battery is missing or incorrect connected

Red and yellow LED 1:
- flashes under soft start

The processor is testing the programme
and after about 5 seconds the main
charging will start

Red and green LED:
- flashes by to high battery voltage while
charging


Battery voltage > 2,9V/C charging charging
switches off


WU: This way of charging can be used for lead/acid batteries, sealed maintenancefree batteries, Ni-Cd batteries and so on by marine and stationary purposes.
  WU have the following meaning:

W : Weak decreasing current
U : Constant voltage
  Main charging will last until the battery is at the gassingpoint. At decreasing current the battery voltage will be held constant. When the charging current is about 30% of main current the yellow LED 2 will illuminate. At the end of the charging event (green LED illuminated) the charging is completed. If the battery remains connected to the battery charger it will get an equalizing current to maintain the battery voltage. At consumption look up section "THE CHARGING EVENT".

TECHNICAL DATA
OPTIONS
  Back to menu:
*
*

*
*
*
*
*
*
*
*
*
*
*
*

*
*
*
*
*
*
*
*
*
Processor controlled
Protected against short circuit and for incorrect pole connections
Soft start
Charging principle according to DIN 41774/41773
Fullautomatic
Thyristor controlled
Degree of protection IP20/IP54
Constant voltage
Adjustable current, adjusted by the manufacture
Adjustable voltage, adjusted by the manufacture
Independent of mains variations
(190-250 volt AC)
75% intermittent use
Connect only to the right DC voltage
Current limited
Voltage limited
3 meter output cable (IP20)
3 meter mains cable (IP20)
Demko approved (IP20)
EMC approved
*
*
*

*

*

*
*
*
*
*
*
*
*
Ammeter
Voltmeter
Casing in degree of protection
up to IP65 or your requires
To build-in, degree of protection
IP00
Alarm, missing mains
Alarm, low battery voltage
Alarm, high battery voltage
Rippelfilter
Temperature regulated charging
Boost
Oscillating charging
Forced-start
As you require

WARNING!
You may not use the battery charger for non recharging batteries. Batteries may generate explosive gas, be careful avoid fire or spark. The battery charger are not designed for charging batteries for cars. Connect the battery charger to earth. The battery charger have to be connected according to present regulation. It may be dangerous to open the battery charger with connected mains.

End of C-Line SYSTEM LM/HE Charging principle WU: Back to menu:






















C-Line Battery Charger for marine and stationary purposes
SYSTEM HE
Charging principle IU
Back to menu:

FULLAUTOMATIC * * * * * * * * * * * SOFT START

GENERAL
The latest development in the electronic area have been used for these battery chargers. The demand of the battery manufactures has been fulfilled, so the battery obtains highest possible capacity.
N.B. The battery charger may only be connected to the DC voltage for which it is designed. (Look up the rating plate).

RANGE OF APPLICATION
Charging of:
Lead/acid batteries
Sealed maintenancefree batteries
Ni-Cd batteries and so on

CHARGING PRINCIPLE, WU
Charges in accordance to DIN 41773,
constant current/constant voltage.


CONNECTION
1. Connect the charging cable to the
battery by a firm connection.
2. Connect the mains.
The charging soft start (red and yellow LED 1 flashes) and after 5 seconds the charging is in function. (Red LED is illuminated).

N.B. The battery charger may only be connected to the DC voltage for which it is designed. (Look up the rating plate).

THE CHARGING EVENT
When the charging has started, the fullautomatic battery charger runs and controls the whole charging event. At consumption the battery charger charges automatically again. The event can be followed by the coloured LED's.



Red LED:
- illuminates by main charging
- flashes by error

Yellow LED 1:
- illuminates when the given voltage
has been reached

Yellow LED 2:
- illuminates by I < 30%

Green LED:
- illuminates when the battery is
fully charged
- flashes if low battery voltage
- flashes for missing battery

Red and yellow LED 1:
- flashing while soft start (about 5 seconds)

DISCONNECTION OF BATTERY
Turn off the mains to the battery
charger if you disconnect the battery.
LED INDICATION: Back to menu:
Red LED:
- illuminates by main charging
- flashes by error
- flashes by to high battery voltage

Mains and battery connected correct

Battery voltage is higher than the
adjusted value
Yellow LED 1:
- lilluminates when the given voltage has been
reached


The gassingpoint of the battery has
been reached

Yellow LED 2:
- illuminates by I < 30%

Main current is less than 30% of
nominal current
Green LED:
- illuminates when the battery is fully charged

- flashes if low battery voltage
- flashes for missing battery

The battery is ready for use
The connected battery voltage < 0,5 V/C

Battery is missing or incorrect connected

Red and yellow LED 1:
- flashes under soft start

The processor is testing the programme
and after about 5 seconds the main
charging will start

Red and green LED:
- flashes by to high battery voltage while
charging


Battery voltage > 2,9V/C charging charging
switches off


IU: This principle of charging can be used for lead/acid batteries, sealed maintenancefree batteries, Ni-Cd batteries and so on by marine and stationary purposes.
  IU have the following meaning:

I : Constant current
U : Constant voltage
  Main charging will last until the battery is at the gassingpoint. At decreasing current the battery voltage will be held constant. When the charging current is about 30% of main current the yellow LED 2 will illuminate. At the end of the charging event (green LED illuminated) the charging is completed. If the battery remains connected to the battery charger it will get an equalizing current to maintain the battery voltage. At consumption look up section
"THE CHARGING EVENT".

TECHNICAL DATA
OPTIONS
  Back to menu:
*
*

*
*
*
*
*
*
*
*
*
*
*
*

*
*
*
*
*
*
*
*
*
Processor controlled
Protected against short circuit and for incorrect pole connections
Soft start
Charging principle according to DIN 41773
Fullautomatic
Thyristor controlled
Degree of protection IP20/IP54
Constant current
Constant voltage
Adjustable current, adjusted by the manufacture
Adjustable voltage, adjusted by the manufacture
Independent of mains variations
(190-250 volt AC)
Connect only to the right DC voltage
Current limited
Voltage limited
3 meter output cable (IP20)
3 meter mains cable (IP20)
Demko approved (IP20)
EMC approved
*
*
*

*

*

*
*
*
*
*
*
*
*
Ammeter
Voltmeter
Casing in degree of protection
up to IP65 or your requires
To build-in, degree of protection
IP00
Alarm, missing mains
Alarm, low battery voltage
Alarm, high battery voltage
Rippelfilter
Temperature regulated charging
Boost
Oscillating charging
Forced-start
As you require

WARNING!
You may not use the battery charger for non recharging batteries. Batteries may generate explosive gas, be careful avoid fire or spark. The battery charger are not designed for charging batteries for cars. Connect the battery charger to earth. The battery charger have to be connected according to present regulation. It may be dangerous to open the battery charger with connected mains.

End of C-Line SYSTEM HE Charging principle IU: Back to menu: